Environmental surveillance of Legionella in tourist facilities of the Balearic Islands, Spain, 2006 to 2010 and 2015 to 2018
More LessBackgroundLegionnaires’ disease is a respiratory illness often associated with hotels and travel. Spain is a major tourist destination and one of the European countries with most cases of Legionnaires’ disease , both community- and travel-associated. However, the prevalence of Legionella in tourist facilities is unknown.
AimThe present investigation aimed to survey the tourist facilities in the Balearic Islands, Spain, for Legionella prevalence.
MethodsWe visited tourist facilities in the Balearic Islands in two different periods (2006–2010 and 2015–2018) and took water samples following national and international guidelines. Legionella was investigated by culture methods following international standards (ISO 11731:1998).
ResultsWe evaluated 13,472 samples from 465 facilities. Bacteria of the Legionella genus were detected in 65.4% of the surveyed facilities. Contamination of the facilities was significantly higher during the second decade (54.5 vs 78.6%). The most frequent colonisers were L. pneumophila serogroup 2–14. We detected the pathogen in 15.9% and 6.9% of hot and cold water distribution systems samples, respectively. The Legionella contamination rate in cold water systems samples was higher when free chlorine levels were < 0.2 mg/L and at > 25 °C temperatures, while in the hot water systems samples, the contamination rate was higher at < 50 °C. Of the samples from hot tubs, 10.9% were contaminated.
ConclusionLegionella prevalence in hotels in the Balearic Islands was high but the contamination rates depended on the installations. Corrective measures are still needed to improve Legionella control.
-
-
-
A community-acquired Legionnaires’ disease outbreak caused by Legionella pneumophila serogroup 2: an uncommon event, Italy, August to October 2018
In September 2018 in Brescia province, northern Italy, an outbreak of Legionnaires' disease (LD) caused by Legionella pneumophila serogroup 2 (Lp2) occurred. The 33 cases (two fatal) resided in seven municipalities along the Chiese river. All cases were negative by urinary antigen test (UAT) and most were diagnosed by real-time PCR and serology. In only three cases, respiratory sample cultures were positive, and Lp2 was identified and typed as sequence type (ST)1455. In another three cases, nested sequence-based typing was directly applied to respiratory samples, which provided allelic profiles highly similar to ST1455. An environmental investigation was undertaken immediately and water samples were collected from private homes, municipal water systems, cooling towers and the river. Overall, 533 environmental water samples were analysed and 34 were positive for Lp. Of these, only three samples, all collected from the Chiese river, were Lp2 ST1455. If and how the river water could have been aerosolised causing the LD cases remains unexplained. This outbreak, the first to our knowledge caused by Lp2, highlights the limits of UAT for LD diagnosis, underlining the importance of adopting multiple tests to ensure that serogroups other than serogroup 1, as well as other Legionella species, are identified.
-
-
-
Provincial trends in Legionnaires’ disease are not explained by population structure in Denmark, 2015 to 2018
More LessBackgroundLegionnaires’ disease (LD) incidence has been increasing in several European countries since 2011. Currently, Denmark is experiencing one of the highest annual incidences of LD despite its relatively cold climate and homogenous population, and the incidence differs notably across the country.
AimWe sought to determine whether provincial differences in LD incidence are attributable to the age and sex distribution of the population, and to characterise the risk of LD by province and age group in Denmark.
MethodsUsing national routine surveillance data for domestic LD cases collected between 2015 and 2018, we assessed the incidence of disease by province and year. Poisson regression models were fit to understand the risk of LD by year and province, as well as by 5-year age groups.
ResultsIncidence of domestic LD increased 48% between 2015 and 2018 across Denmark. Some provinces continuously had a high incidence of disease, even after adjusting for yearly trends and the underlying population distribution. Variations in the proportion of the population aged 65 years and older were not responsible for the increase in disease in our analysis. Finally, incidence of disease increased with each 5-year age group in both men and women.
ConclusionsThe relative differences in incidence between Danish provinces could not be explained by the age and sex distribution of the population, indicating that other factors must be responsible for the varying incidence across the country. These results may help inform trends in other countries in Europe also experiencing an unexplained high incidence of LD.
-
-
-
An outbreak investigation of Legionella non-pneumophila Legionnaires’ disease in Sweden, April to August 2018: Gardening and use of commercial bagged soil associated with infections
In early June 2018, an increase in non-travel-related cases of Legionella non-pneumophila Legionnaires’ disease (LD) was observed in Sweden and a national outbreak investigation was started. Outbreak cases were defined as notified confirmed or probable cases of L. non-pneumophila LD, with symptom onset after 1 April 2018. From April to August 2018, 41 cases were reported, 30 of whom were identified as L. longbeachae. We conducted a case–control study with 27 cases and 182 matched controls. Results from the case–control study indicated that gardening and handling commercial bagged soil, especially dusty dry soil, were associated with disease. L. longbeachae was isolated in soils from cases’ homes or gardens, but joint analysis of soil and human specimens did not identify any genetic clonality. Substantial polyclonality was noted between and within soil samples, which made finding a genetic match between soil and human specimens unlikely. Therefore, whole genome sequencing may be of limited use to confirm a specific soil as a vehicle of transmission for L. longbeachae. Handling soil for residential gardening was associated with disease and the isolation of L. longbeachae in different soils provided further evidence for Legionella non-pneumophila infection from soil.
-
-
-
-
Legionella pneumonia: increased risk after COVID-19 lockdown? Italy, May to June 2020
We report a case of Legionella pneumonia in a dishwasher of a restaurant in Rome, Italy, just after the end of the lockdown that was in place to control the SARS-CoV-2 epidemic. The case highlights the importance of strict monitoring of water and air systems immediately before reopening business or public sector buildings, and the need to consider Legionella infections among the differential diagnosis of respiratory infections after lockdown due to the ongoing COVID-19 pandemic.
-
-
-
Large community-acquired Legionnaires’ disease outbreak caused by Legionella pneumophila serogroup 1, Italy, July to August 2018
Marino Faccini , Antonio Giampiero Russo , Maira Bonini , Sara Tunesi , Rossella Murtas , Monica Sandrini , Sabrina Senatore , Anna Lamberti , Giorgio Ciconali , Serafina Cammarata , Eros Barrese , Valentina Ceriotti , Sonia Vitaliti , Marina Foti , Gabriella Gentili , Elisabetta Graziano , Emerico Panciroli , Marco Bosio , Maria Gramegna , Danilo Cereda , Carlo Federico Perno , Ester Mazzola , Daniela Campisi , Gianuario Aulicino , Silvana Castaldi , Antonietta Girolamo , Maria Grazia Caporali , Maria Scaturro , Maria Cristina Rota and Maria Luisa RicciIn July 2018, a large outbreak of Legionnaires’ disease (LD) caused by Legionella pneumophila serogroup 1 (Lp1) occurred in Bresso, Italy. Fifty-two cases were diagnosed, including five deaths. We performed an epidemiological investigation and prepared a map of the places cases visited during the incubation period. All sites identified as potential sources were investigated and sampled. Association between heavy rainfall and LD cases was evaluated in a case-crossover study. We also performed a case–control study and an aerosol dispersion investigation model. Lp1 was isolated from 22 of 598 analysed water samples; four clinical isolates were typed using monoclonal antibodies and sequence-based typing. Four Lp1 human strains were ST23, of which two were Philadelphia and two were France-Allentown subgroup. Lp1 ST23 France-Allentown was isolated only from a public fountain. In the case-crossover study, extreme precipitation 5–6 days before symptom onset was associated with increased LD risk. The aerosol dispersion model showed that the fountain matched the case distribution best. The case–control study demonstrated a significant eightfold increase in risk for cases residing near the public fountain. The three studies and the matching of clinical and environmental Lp1 strains identified the fountain as the source responsible for the epidemic.
-
-
-
Factors associated with Legionnaires’ disease recurrence in hotel and holiday rental accommodation sites
BackgroundThe detection of a cluster of travel-associated Legionnaires’ disease (TALD) cases in any European Union/European Economic Area (EU/EEA) country prompts action at the accommodation, follow-up by health authorities and reporting of measures taken. Some accommodations incur further cases despite presumed implementation of adequate control measures.
AimTo identify factors associated with the occurrence of a further TALD case after the implementation of control measures.
MethodsWe conducted a retrospective cohort study of hotel and holiday rental accommodations in the EU/EEA associated with two or more TALD cases with onset dates less than 2 years apart (a ‘cluster’) and notification between 1 June 2011−31 December 2016. We fitted Cox regression models to estimate the association between accommodation characteristics and the occurrence of a further case, defined as any case with onset date after the report on measures taken.
ResultsOf the 357 accommodations in the analysis, 90 (25%) were associated with at least one further case after the report on measures taken (12.4/100 accommodation-years). Accommodations associated with two or more cases before the cluster notification were more likely to be associated with a further case, compared with those not previously associated with any case (adjusted hazard ratio 1.85; 95% confidence interval: 1.14–3.02). Neither the detection of Legionella in the water system nor the type of disinfection were found to be associated with the risk of a further case.
ConclusionAccommodation size and previous TALD cases were predictive of further Legionnaires’ disease cases after implementation of control measures.
-
-
-
Air-conditioner cooling towers as complex reservoirs and continuous source of Legionella pneumophila infection evidenced by a genomic analysis study in 2017, Switzerland
IntroductionWater supply and air-conditioner cooling towers (ACCT) are potential sources of Legionella pneumophila infection in people. During outbreaks, traditional typing methods cannot sufficiently segregate L. pneumophila strains to reliably trace back transmissions to these artificial water systems. Moreover, because multiple L. pneumophila strains may be present within these systems, methods to adequately distinguish strains are needed. Whole genome sequencing (WGS) and core genome multilocus sequence typing (cgMLST), with their higher resolution are helpful in this respect. In summer 2017, the health administration of the city of Basel detected an increase of L. pneumophila infections compared with previous months, signalling an outbreak.
AimWe aimed to identify L. pneumophila strains populating suspected environmental sources of the outbreak, and to assess the relations between these strains and clinical outbreak strains.
MethodsAn epidemiological and WGS-based microbiological investigation was performed, involving isolates from the local water supply and two ACCTs (n = 60), clinical outbreak and non-outbreak related isolates from 2017 (n = 8) and historic isolates from 2003–2016 (n = 26).
ResultsIn both ACCTs, multiple strains were found. Phylogenetic analysis of the ACCT isolates showed a diversity of a few hundred allelic differences in cgMLST. Furthermore, two isolates from one ACCT showed no allelic differences to three clinical isolates from 2017. Five clinical isolates collected in the Basel area in the last decade were also identical in cgMLST to recent isolates from the two ACCTs.
ConclusionCurrent outbreak-related and historic isolates were linked to ACCTs, which form a complex environmental habitat where strains are conserved over years.
-
-
-
Improvement of Legionnaires’ disease diagnosis using real-time PCR assay: a retrospective analysis, Italy, 2010 to 2015
AimTo evaluate real-time PCR as a diagnostic method for Legionnaires’ disease (LD). Detection of Legionella DNA is among the laboratory criteria of a probable LD case, according to the European Centre for Disease Prevention and Control, although the utility and advantages, as compared to culture, are widely recognised.
MethodsTwo independent laboratories, one using an in-house and the other a commercial real-time PCR assay, analysed 354 respiratory samples from 311 patients hospitalised with pneumonia between 2010–15. The real-time PCR reliability was compared with that of culture and urinary antigen tests (UAT). Concordance, specificity, sensitivity and positive and negative predictive values (PPV and NPV, respectively) were calculated.
ResultsOverall PCR detected eight additional LD cases, six of which were due to Legionella pneumophila (Lp) non-serogroup 1. The two real-time PCR assays were concordant in 99.4% of the samples. Considering in-house real-time PCR as the reference method, specificity of culture and UAT was 100% and 97.9% (95% CI: 96.2–99.6), while the sensitivity was 63.6% (95%CI: 58.6–68.6) and 77.8% (95% CI: 72.9–82.7). PPV and NPV for culture were 100% and 93.7% (95% CI: 91.2-96.3). PPV and NPV for UAT were 87.5% (95% CI: 83.6-91.4) and 95.8% (95% CI: 93.5-98.2).
ConclusionRegardless of the real-time PCR assay used, it was possible to diagnose LD cases with higher sensitivity than using culture or UAT. These data encourage the adoption of PCR as routine laboratory testing to diagnose LD and such methods should be eligible to define a confirmed LD case.
-